AIR BLASTER INSTALLATION

Air Blaster Installation

Efficient, reliable and high-performance air blaster installation solutions for industrial applications.

ABOUT AIR BLASTER INSTALLATION

Powerful Cleaning Solutions for Industrial Applications

Air Blaster is very effective and economical method of removing jamming in Bunkers, make Chutes, Kiln Inlet, Coolers, Chutes, Hoppers and Silos etc. and it ensures smooth and continuous flow of materials. It can be installed at any place and its operation is very simple. Even an unskilled worker can operate it with full satisfaction. It works on compressed air 5-7Kg/cm² which is delivered through pipe lines. Generally plant air is adequate. In case when plant air is not available at the site, small compressor or can be installed as per the requirement for operation of Air Blaster is not much. It is operated when jamming takes place. By installing this equipment's, hazardous manual poking with rod can be avoided. The cost of installing Air Blasters is quickly recovered through the increased efficiency and reduces down time from the creation of free material flow. EVEN A SINGLE PREVENTED ACCIDENT CAN PAY FOR A COMPLETE INSTALLATION.

Operating Sequence – Pre-Heater Riser Duct

Operating Sequence of Air Blasters should be maintained from TOP to BOTTOM in case of Pre-heater Riser Duct.

Operating Sequence – Hopper, Bunker, Chute etc.

Operating Sequence of Air Blasters should be maintained from BOTTOM to TOP in case of Hopper, Bunker, Chute, Cyclone etc.

APPLICATIONS

Where Air Blasters Are Used

air-Installation-1

Air Blasters installed for removing coating in Cyclone-Riser Duct Bend.

air-Installation-2

Air Blasters installed for removing coating in Grate Cooler.

air-Installation-3

Air Blasters installed for removing coating in Pre-Heater Inlet Chamber (Duct).

air-Installation-4

Heat recovery process in Co-generation from D.G. Sets.

PRODUCTS RANGE

Air Blaster Specifications

MODEL DISCHARGE TANK CAP (LITERS) FAD AT(7kg/cm2)
(in liters)
APPLICATION
AB-05-020 050mm 20 140 Chutes, Small Section
AB-10-050 100mm 50 350 Chutes, Feed Pipes
AB-10-070 100mm 70 490 Chutes, Feed Pipes, Cyclone
AB-10-100 100mm 100 700 Feed Pipe, Cyclone & Riser Duct
AB-10-150 100mm 150 1050 Cyclone, Riser Duct, Cooler, Hopper
AB-10-300 100mm 300 2100 Cooler, Hoppers, Bunkers, Silos
AB-15-150 150mm 150 1050 Cooler, Hoppers, Bunkers, Silos
AB-15-300 150mm 300 2100 Cooler, Hoppers, Bunkers, Silos